نصب شدہ پمپ کو صاف کرنے کے لیے، پمپ بند کرنے کے طریقہ کار پر عمل کریں:
Feb 24, 2022| نصب شدہ پمپ کو صاف کرنے کے لیے، پمپ بند کرنے کے طریقہ کار پر عمل کریں:
1. Remove all water cooling lines and cut off the primary circuit power supply to the pump heater. 2. Release all pump oil. 3. Unscrew the inlet and front pipe connection bolts and remove the pump from the system. 4. Remove the water cooling cap (if applicable). 5. Remove the nozzle assembly in accordance with the method described in the operation manual of the specific pump model. 6. Carefully clean the inside of the pump body with acetone and flush with isopropyl alcohol. The pump is then blown dry with clean, dry, oil-free compressed air. 7. Carefully clean nozzle assembly with acetone. Wipe all surfaces with isopropyl alcohol and blow dry them with clean, dry, oil-free compressed air. 8. Reinstall the nozzle and water cooling cap to the pump body. Make sure the nozzle is properly aligned with the front stage system (if applicable). 9. Check the condition of o-rings. Replace o-rings that show any signs of aging or compression. 10. Connect the pump to the system.
انتباہ:
کسی اعلی-درجہ حرارت کے ذریعہ کے قریب استعمال نہ کریں۔ کام کی جگہ کو پنکھے کے ساتھ ہوادار کریں اور ایک بڑے کنویں-ہوادار کمرے میں ڈفیوژن پمپ کا استعمال کریں۔ اگر ضروری ہو تو الگ سانس لینے کا سامان بھی استعمال کیا جا سکتا ہے۔
ہمیشہ اس بات کو یقینی بنائیں کہ صفائی کے کام ایک بڑے، اچھی-ہوادار کمرے میں کیے جائیں۔ براہ کرم چشمیں، دستانے اور حفاظتی لباس پہنیں۔

IKS PVD کمپنی، آرائشی کوٹنگ مشین، ٹولز کوٹنگ مشین، DLC کوٹنگ مشین، آپٹیکل کوٹنگ مشین، PVD ویکیوم کوٹنگ لائن، ٹرن-کلیدی پروجیکٹ دستیاب ہے۔ ابھی ہم سے رابطہ کریں، ای-میل:iks.pvd@foxmail.com